● Universal AC input ● Overload protection
● High power density ● Over voltage protevtion
● Compact designer ● Short circuit protevtion
● Convection cooled ● LED power indicator
● DIN rail ● Made of double-sided PCB
● Great reliability
ADP-24V-1A
● Universal AC input ● Overload protection ● High power density ● Over voltage protevtion ● Compact designer ● Short circuit protevtion ● Convection
| Specification | ADP-24V-1A | ||
| Input | Input voltage | 100~240Vac | |
| Frequency | 50/60Hz | ||
| Maximum input current | 1A max. | ||
| Inrush current (cold start) | 22A/115Vac (44A/230Vac) | ||
| Output | Rated output power | 24W | |
| Output voltage | 24V | ||
| Output current | 1A | ||
| Output voltage range | 23.6~27.4V(adjustable) | ||
| Conversion efficiency | 87%/110Vac,86%/110Vac | ||
| Output ripple | 55mv max.* | ||
| Output noise | 70mv max.* | ||
| Hold-up time | 20ms以上/110Vac,60ms以上/220Vac | ||
| Startup time | 35ms以上/110Vac,30ms以上/220Vac | ||
| Protection | Overload protection | Method | Foldback overload protection,automatically recover when overload is removed |
| Overload | 108%~145% rated output power | ||
| Over voltage protection | Method | Latching overvoltage protection, re-power on to recover | |
| Overvoltage | 33V~40V | ||
| Short circuit protection | Overload protection | ||
| Certifications | CE | EMC & LVD | |
| Environmental | Operating temperature | -20℃~45℃ | |
| Operating humidity | Non-condensing 20%~90% | ||
| Note | Output ripple & noise are measured by a 20MHz bandwidth oscilloscope under the output terminals are connected in parallel with a 0.1uF ceramic & a 47 uF electrolytic capacitors. | ||
| Output voltage | 24 V |
|---|---|
| Output Current | 1 A |
| Installation mode | DIN RAIL |
Reviews
There are no reviews yet.

فارسی

Be the first to review “ADP-24V-1A”
You must be logged in to post a review.